Purpose |
Automate measurement of flow in pulmonary artery |
Tag(s) |
#Qp:Qs |
Panel |
Cardiac |
Define-AI ID |
18040021 |
Originator |
Benoit Desjardins |
Panel Chair |
Carlo De Cecco |
Panel Reviewers |
Cardiac Panel |
License |
|
Status | Published |
Procedures(s): MRI, Cardiac
View(s): CMR velocity-encoded phase contrast images, pulmonary artery
Sex at Birth: {Male, Female}
Age (years): [0,90]
Intervention: {Congenital heart disease repair, mitral valve replacements}
Comorbidities: {Congenital heart disease, Ventricular septal defects}
Body Surface Area (m2): [1,3.5]
Body Mass Index (kg/m2): [10,52]
Pulmonary artery diameter (mm): [10,50]
Procedure |
MRI, Cardiac |
Views |
CMR velocity-encoded phase contrast images, pulmonary artery |
Data Type |
DICOM |
Modality |
MR |
Body Region |
Chest |
Anatomic Focus |
Heart |
RadElement ID |
RDE297 |
Definition |
Measurement of net flow volume in the pulmonary artery above the aortic valve |
Data Type |
Numeric |
Value Set |
|
Units |
mL/sec |
RadElement ID |
|
Definition |
Measurement of maximum flow velocity in the pulmonary artery above the aortic valve |
Data Type |
Numeric |
Value Set |
|
Units |